The 401 Waterloo Multilevel System
It allows detailed groundwater monitoring from many zones in one borehole.The System is modular to allow ports to be located accurately at desired monitoring zones. The zones are permanently isolated by packers or seals and each port is individually connected to the surface.
Ports can be fitted with dedicated Transducers, Bladder Pumps and/or Double Valve Pumps. Alternatively, a port may be fitted with a monitoring tube that is left open for use with narrow diameter portable equipment, such as the 102 or Mini 102 Water Level Meter and a narrow diameter Inertial Pump, a Peristaltic Pump or the Micro Double Valve Pump.
Ports, packers and casing lengths are assembled, as needed, into a water-tight PVC or stainless steel casing string. The modular Waterloo System allows complete customization to each application. Systems can be installed on an angle or vertically. A drilling rig is not necessarily required during installation. Monitoring is fast and efficient, especially if dedicated equipment is used.
-
The 403 CMT® Multilevel System
It provides the simplicity and low cost of a bundle-type installation, with the benefits of backfilling or sealing around a single tube, with no joints.
The CMT System uses continuous polyethylene multichannel tubing which is custom-built on site with screened intervals at desired sampling zones. CMT Systems are inexpensive and easy to install. In-field design flexibility allows the number of monitoring ports, port locations, and monitoring strategy to be finalized right on site.
Monitor up to 7 discrete zones in the 1.7″ (43 mm) System and 3 zones in the narrow 1.1″ (28 mm) System. Reliable seals and sand packs can be placed using standard backfill methods, or using pre-formed cartridges in the 3-Channel System.
Water levels can be accurately established and samples taken using small diameter portable equipment available from Solinst. Special wellhead seals are also available to allow vapor sampling.